Auto-Ranging Clamp Meter: The meter measures AC current to 600 amp, AC and DC Voltage to 600 V, Resistance to 40MΩ, and Capacitance to 4MF. Does not measure DC Current.
True-RMS Amp Meter: The sensing meter accurately measures distorted waveforms and provides true readings when measuring linear or non-linear loads.
Advanced Functions: Auto-off of inactivity after 15 minutes, Data Hold, MAX/MIN Reading, Low Battery Indicator, and Continuity Loud Buzzer.
Two-Color Backlight and Work Light: Two-color backlit LCD Display - When the voltage > 80V, the current > 3A, the LCD backlit screen turns orange to warn you, The LCD Backlit Screen and Work Light make it easy to use in a dark working area.
Superior Safety and Service: Standard IEC 61010-1, CAT III 600V. Double insulation. 36 Months of product service provided. 7/24 Customer Service.
Specifications | Range | Accuracy |
---|---|---|
DC Voltage | 400mV/4V/40V/400V/600V | ±(0.5%+5) |
AC Voltage | 4V/40V/400V/600V | ±(1.0%+5) |
AC Current | 4A/40A/600A | ±(2.5%+8) |
Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | ±(1.0%+5) |
Capacitance | 4nF/40nF/400nF/44F/40μF/400μF/4mF | ±(4.0%+5) |
Frequency | 10Hz/100Hz/1kHz/10kHz/100kHZ/1MHz/10MHz | ±(1.0%+3) |
Duty | 1%~99% | ±(3.0%+3) |
Temperature | -40°C-1000°C | ±(1.0%+2) |
-40°F~1832°F | ±(1.0%+2) | |
Counts | 4000 |
- USER MANUAL
- Download
- PATENT CERTIFICATE
- →     LD01-Test Report
- →     LD01-Certificate
- SPECIFICATION
- Item Weight
- 0.43 KG
- Product Dimensions
- 7.5 x 2.8 x 1.3 inches
- Batteries
- 2 AAA batteries required
- Security standard
- IEC 61010-1, IEC 61010-2-032 IEC 61010-030, IEC61010 CAT.III 600V
- Upgraded Specification
-
● DC Voltage: 400mV / 4V / 40V / 400V / 600V Accuracy: ±(0.5%+5)
● AC Voltage: 4V / 40V / 400V / 600V Accuracy: ±(1.0%+5)
● AC Current: 4A / 40A / 400A / 600A Accuracy: ±(2.5%+5)
● Resistance: 4nF / 40nF / 400nF / 4uF / 40uF / 400uF / 4mF Accuracy: ±(4.0%+5)
● Capacitance: 4nF / 40nF / 400nF / 4uF / 40uF / 400uF / 4mF Accuracy: ±(4.0%+5)
Mosaiminse
Multi-Function
Accurately measure resistance, capacitance, diode, continuity. Easy to use in laboratory factories and homes.
Mosaiminse
Why can't I directly test the power cord?
There will be no reading if you directly test the power cord. You need to use an AC line splitter tool separates the neutral and the hot wire.
Mosaiminse
Advanced Function
Hold Function
Freezes the display reading. Reading is released when button is pushed a second time.
Automatic Shutdown
If there is no operation within 15 minutes, the clamp meter will automatically shut down. Effectively save power.
Flashlight and Word Light
In a dark environment, turn on the flashlight and backlight, you can easily work.
Mosaiminse
Can DC current be measured?
NO. This meter can only measure AC Current.
Mosaiminse
What will you get?
1 x Mosaiminse HT206A Digital Clamp Meter
2 x Test Leads
2 x AAA Batteries (Assembly Required)
1 x User Manual
1 x Clamp Meter Bag